Suburban’s name is synonymous for quality products that enhance the RV lifestyle and is known for reliable performance, longevity and unparalleled service. Our product expertise have kept us at the forefront of the industry and has made us a trusted and committed partner to RV manufacturers, dealers and enthusiasts everywhere. Suburban DD-17DSI Pdf User Manuals. View online or download Suburban DD-17DSI Service Manual, Owner's Information Manual. Electronic Ignition De;cription Thermostat Yectrode Limit Switch. Module Board Fan Switch. Relay Vent Cap Assembly. Burner Assembly.
Download Service manual of Suburban Mfg DD-17DSI Furnace for Free or View it Online on All-Guides.com. This version of Suburban Mfg DD-17DSI Manual compatible with such list of devices, as: NT-40, SF-30, SH-35, SH-35F, SH-42
Brand: Suburban Mfg
Category: Furnace
Type: Service manual
Model: Suburban Mfg DD-17DSI , Suburban Mfg DD-17DSIW , Suburban Mfg NT-12S/SE , Suburban Mfg NT-16S/SE , Suburban Mfg NT-20S/SE , Suburban Mfg NT-24SP , Suburban Mfg NT-30SP , Suburban Mfg NT-34SP , Suburban Mfg NT-40 , Suburban Mfg P-30S/40 , Suburban Mfg SF-20 , Suburban Mfg SF-20F , Suburban Mfg SF-25 , Suburban Mfg SF-25F , Suburban Mfg SF-30 , Suburban Mfg SF-30F , Suburban Mfg SF-35 , Suburban Mfg SF-35F , Suburban Mfg SF-42 , Suburban Mfg SF-42F , Suburban Mfg SFV-35 , Suburban Mfg SFV-35F , Suburban Mfg SFV-42 , Suburban Mfg SFV-42F , Suburban Mfg SH-35 , Suburban Mfg SH-35F , Suburban Mfg SH-42 , Suburban Mfg SH-42F , Suburban Mfg SHD-2542
Pages: 40
TABLE OF CONTENTS
General Service Information...........................................................3
Furnace Spec Sheet.................................................................4
Installation........................................................................5
Vent Assembly Illustrations........................................................ 6-16
Return Air Illustrations..............................................................16
Ducting Illustrations................................................................17
Installation Requirements (DD, NT and P Model Furnaces).................................18
Installation Requirements (SF, SH and SHD-2542 Model Furnaces). .........................19

Installation Requirement (SFV Model Furnaces)..........................................20
Furnace Specifications (DD, NT and P Model Furnaces)...................................21
Furnace Specifications (SF, SFV, SH, and SHD-2542 Model Furnaces).......................22
Sequence of Operation (Time Delay Relay Equipped Furnaces).............................23

Sequence of Operation (Fan Control Module Board (520820) Equipped Furnaces)...............24
Sequence of Operation (24 VAC Fan Control Module Board (520947).........................25
Sequence of Operation (SHD-2542 Furance)............................................26
Trouble Shooting Flow Chart (Furnaces Equipped with Time Delay Relay). . . . . . .. . . . . . .. . . . . . .27
Trouble Shooting Flow Chart (Furnaces Equipped with Fan Control Module Board)..............28
for Suburban 24-Volt AC Electronic Ignition Furnaces............................29-30
Wiring Diagrams................................................................ 30-34
Furnace Removal............................................................... 35-36
SF, SH and SHD-2542 Electrode Gap Specifications & Positioning...........................37
NT and Park Model Electrode Gap Specifications & Positioning . ............................38
Maintenance......................................................................39
Cautions & Safety Information................................................Back Cover
NOTE: Our service technicians are available to assist you in making repairs or parts replacements
from 8:00 a.m. to 5:00 p.m. Eastern Standard Time, Monday through Friday (except holidays), by
calling 423-775-2131 extension 7102. E-mail address: info1@suburbanmfg.com
Related Products for Suburban DD-17DSI
Related Manuals for Suburban DD-17DSI
Suburban DD-17DSI: Frequently viewed Manuals
Download Service manual of Suburban Mfg DD-17DSI Furnace for Free or View it Online on All-Guides.com. This version of Suburban Mfg DD-17DSI Manual compatible with such list of devices, as: DD-17DSIW, SF-20, SFV-35F, SH-35F, SHD-2542
Brand: Suburban Mfg
Category: Furnace
Type: Service manual
Model: Suburban Mfg DD-17DSI , Suburban Mfg DD-17DSIW , Suburban Mfg NT-12S/SE , Suburban Mfg NT-16S/SE , Suburban Mfg NT-20S/SE , Suburban Mfg NT-24SP , Suburban Mfg NT-30SP , Suburban Mfg NT-34SP , Suburban Mfg NT-40 , Suburban Mfg P-30S/40 , Suburban Mfg SF-20 , Suburban Mfg SF-20F , Suburban Mfg SF-25 , Suburban Mfg SF-25F , Suburban Mfg SF-30 , Suburban Mfg SF-30F , Suburban Mfg SF-35 , Suburban Mfg SF-35F , Suburban Mfg SF-42 , Suburban Mfg SF-42F , Suburban Mfg SFV-35 , Suburban Mfg SFV-35F , Suburban Mfg SFV-42 , Suburban Mfg SFV-42F , Suburban Mfg SH-35 , Suburban Mfg SH-35F , Suburban Mfg SH-42 , Suburban Mfg SH-42F , Suburban Mfg SHD-2542
Pages: 40
Suburban
12 VDC DirectBTU/hShipping
NT-12SE12,0009 3/8'9 3/8'21-27 3/4'Electronic27
NT-20SE19,0009 3/8'9 3/8'21-27 3/4'Electronic27
AccessoriesDescription
260198Vent Kit 4' - 6' DD Models
12 VDC DuctedBTU/hShipping
NT-12S12,0009 3/8'9 3/8'22 3/4-29 1/2'Electronic27
NT-16S16,0009 3/8'9 3/8'22 3/4-29 1/2'Electronic27
NT-20S19,0009 3/8'9 3/8'23 3/8-30 1/8'Electronic27
NT-30SP30,00012 1/2'12'23'Electronic40
NT-4040,00012 1/2'12'23'Electronic42
SF-25F25,0007 1/2'17'20'Electronic35
SF-35F35,0007 1/2'17'20'Electronic35
SH-35F35,0009 1/4'17'20'Electronic40
SF-20*20,0007 1/2'17'20'Electronic35
SF-30*30,0007 1/2'17'20'Electronic35
SF-42*40,0007 1/2'17'20'Electronic35
SH-42*40,0009 1/4'17'20'Electronic42
AccessoriesDescription
6258ACW*Door, Optional Access, Colonial White, Standard SF Models
6258APW*Door, Optional Access, Polar White, Standard SF Models
6267ACW*Door, Optional Access, Colonial White, Standard SH Models
Model FurnacesInputHeightWidthDepthIgnitionWeight
AccessoriesDescription
050715Duct Collar 4'

280552Rain Shield
Suburban Dd17dsi Manual Transmission
062164Bottom Duct Gasket, NT-24/30/34SP, NT-40, P40
070853Bottom Duct Gasket, SF Models Except SF-42, (F)
520009Bottom Duct Kit W/Gasket, NT-24/30/34SP, NT-40. P40
Suburban Dd17dsi Manual 2016
520576Bottom Duct Kit W/Gasket, SF Models Except SF-42, (F), SH35 (F)
520753Bottom Duct Kit W/Gasket and Door, SF-42, (F)
Wall Thermostats are included with All Models, except SF.
Vent Assemblies are included with all units, except DD.
Related Products for Suburban DD-17DSI
Related Manuals for Suburban DD-17DSI
Suburban Dd17dsi Manual Free